ENFC NATURAL SMOKE AND HEAT EXHAUST VENTILATOR
SMOKE LUX
UNI EN 12101-2 – UNI 9494-1
Reliability
Opening under snow load
Wind load
Heat resistance
Low-temperature test
Re 300 cicli
SL 500/1000
WL 1500
B 300° C
T 00/T -15
Reliability: Re 300 cycles
Opening under snow load: SL 500 / 1000
Wind load: WL 1500
Heat resistance: B 300 °C
Low-temperature test: T 00 / T −15
Manufactured with a frame and counterframe in natural extruded aluminum profiles; pneumatic cylinder with variable bore and stroke, mounted on a special galvanized steel tilting carriage allowing an opening angle from 140° to 165°.
Supplied complete with an electromagnetic valve with thermofusible vial calibrated at 68°, a CO₂ cartridge of suitable capacity, and a patented mechanical locking hook with release on opening. Equipped with copper and stainless steel–clad Teflon fittings, external opening for maintenance via a steel eyelet, and a mechanical locking system to secure the unit in the event of adverse wind conditions.